Common failure analysis of AD matrix

Date: 2018/4/7Number Of Times Read: 1587
1. When the AD matrix alarm linkage is connected, why can't the police linkage group switch be realized, and only the corresponding camera number of the alarm can be called?
Alarm linkage group switch, monitor protection type can only be set to BSI, BSA, BSM, BHI, BHA, BHM, and behind the protection type number is the number of monitor group, if 1, 2, 3, three monitors are in a group, then the serial number will be changed to the same.
2. Can the AD matrix be upgraded through the web page?
You can. Select the ramdisk file that needs to be uploaded after entering the webpage, and then choose to restore the factory Settings button after uploading. Note: never choose to restart, if you choose to restart, you need to delete old files via the super terminal.
3. AD software USES alarm module to alarm, the monitor status of the matrix setting is SSI and SSA, the alarm signal is cancelled on AD5500 software, the matrix still shows the alarm, how to set it correctly?
In the matrix Settings, the monitor state is set to automatic mode (SSI, SSA), and the latter is manually enabled to be opened; Alternatively, the monitor state is set to the manual mode (SSM).
4. AD matrix, the monitor output can be displayed normally when the keyboard LAST and the NEXT key are turned on page, and why does the CAM of the keyboard show no change?
The use of serial port, if not set to the keyboard, will result in the operation, other functions are normal, except for the keyboard LAST and the NEXT key to turn the page, the keyboard display CAM has not changed.
5. Ad1024x-608v48, the fourth chassis switch CPU, the board card information shows "error", and the output of 33-48 is no video?
The range of the camera and monitor set by the output plate dial and the scope of the camera and monitor in the 6.1 menu are inconsistent.
6. How does the video loss detection function of AD be forwarded to the network?
The output V2060 video loss detection function is automatically forwarded to site 512, and V2060 only forwards this information. As for the processing of this information, it needs to be handled by the receiving party.
7. Ad2040nx168-17 matrix, when all video is switched on 1-4mon, the characters can be switched out, but the image does not change. What is the reason?
1-4mon's output board, the customer's jumper cap jumps in the wrong position, causing the image to remain unchanged.
8. AD sets the group switch, can the remote camera and local camera be set in a group switch?
You can do this, but if you need to set a remote camera in a group switch, you need to have plenty of channels.
9. AD matrix, with the keyboard LAST and NEXT key, the monitor output can display normally, why does the keyboard display CAM not change?
Changed the purpose of the serial port, not set into the keyboard, led to the LAST of the keyboard and the NEXT key pages, monitor output to normal display, display and keyboard CAM did not change, set the serial port function into other functions, other function is normal, only the LAST of the keyboard and the NEXT key pages, keyboard display CAM did not change.